علت روشن نشدن پکیج بوتان
The reasons for not turning on the butane package can be due to the lack of package load pressure. And you can increase the pressure of the device by one and a half with the lever that is under the device (filling valve).
and other reasons such as the gas valve being closed or the gas supply to the building being cut off, the power cut of the beta model butane package, the circulation pump being sour, among the most common reasons.
Not turning on the butane package is Perlapro model.
Butan package errors, Kalda Vizia model
But if you notice that when you turn on the Butane Parma package, the red light of the package is activated, the reason why this light turns on can be due to the defective sensor of the heating circuit, or the lack of detection or the formation of a flame by ions.
Also, the reasons for not turning on the Bhutan package can be due to the error codes that happen to this package. If you live in Alborz province, go to Package Vocational Technical School in Karaj and enroll in specialized classes.
The reason for not turning on the packages:
In the following educational articles on package repair and service, we are going to examine one of the common problems that arise in different package models.
If you see that your package does not turn on, the first thing you do is to check the water pressure through the valves.
Also, check the gas pressure, if there is no problem with the water pressure and gas pressure entering the package, the problem is probably with the device itself or the piping system and heaters connected to the package.
In this case, you can service and troubleshoot the package by getting advice from a professional package repairer.
https://www.aparat.com/v/AdVOT
In addition, in some of the package models that we will review below, the packages that have a display screen inform you of the problem in the package by announcing the error code, in the rest of this article the reason for the package not turning on We check different.

علت روشن نشدن پکیج ایران رادیاتور
Iran radiator package not turning on can be due to the following reasons:
1: Low flame height
2: Having air in the radiator system
3: Lack of proper circulation of water in the system due to pump defects
4: Low package load pressure
5: Sedimentation of converters and radiators of the Iran radiator package
6: Iran radiator package thermostat failure
7: Not using the standard piping system for Iran Radiator package radiators
8: Iran radiator package board damage
https://amozesh-alborz.ir/
علت روشن نشدن پکیج گلدیران
If you are using Goldiran model packages, the reasons for not turning on the Goldiran package are due to using the package at a temperature below 60 degrees Celsius, installing inappropriate filters in
Cold water inlet or filter called polyphosphate filter.
Not using the return filter and not cleaning it every once in a while can cause the Goldiran package not to turn on.
Also, not injecting anti-fouling solution into the radiator system of Goldiran package can cause this package to turn on.
which must be injected into the system of radiators of the Helmand anti-fouling solution at the time of Goldiran package service, and you must remember that this point must be reported to the package service
Please note flower growers.
علت روشن نشدن پکیج تاچی
Failure to turn on the Tachi package is due to the lack of enough water in the circuit and pipes of the package, all packages are equipped with an automatic shutdown system by default, and one of the things that
It causes the system to be activated due to the lack of water pressure in the Tachi package, which you can check the amount of water pressure in the tank through the hand indicator that is always under the package.
https://www.aparat.com/v/AdVOT
علت روشن نشدن پکیج ایساتیس در حالت تابستانه آموزشگاه پکیج در کرج
Isatis package not turning on in summer mode can be due to the following reasons:
1: Low package load pressure
https://www.aparat.com/v/AdVOT
2: failure of the flow switch or flow meter or burning of the finger of the flow meter
3: Engine valve burning and staying on winter mode
4: Defective circuit sensor
5: Failure of air pressure switch or stuck fan impeller
6: Defective bypass valve spring
7: Pump failure in the package of two converters
8: Sedimentation of the secondary converter
9: Failure of the control board